Teledyne LeCroy Sierra M6-2 SAS_SATA Protocol Analyzer User Manual User Manual

Page 147

Advertising
background image

    

Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual

145

Emulation

Teledyne LeCroy

Figure 2.134: Outgoing Frame Settings

Frame Type Error

Check this to introduce a frame type error.

Remove Frame from sequence

Check this to remove frame from sequence.

Delay in sending frame

Check this to delay sending frame and enter a value for the delay.

Frame Length Error

Check Frame Length Error and choose the type of error to introduce.

Code violation and Disparity error

Check these and specify DWORD offset and number of error DWORDs.

Additionally check:

No WTRM
Code Violation on SATA primitive
Disparity error on SATA primitive
Ignore XRDY/RRDY sequence
Delay in HOLD response (in sending HOLDA)

SOF, EOF and CRC errors

Check these and specify Double or Omit by checking the corresponding option button.

Advertising