Manual Operation

To Close Any Switch in the System (to select a channel)

To Close Any Switch in the System

(to select a channel)

To manually close a switch (to select a channel):

1. Press:

[Select Instr] {85330A}

2. If the

{CLOSE}

softkey does not appear, press:

[Prev Menu]

(until it does)

3. Press:

{CLOSE}

a.

If the switch you want to close is connected to PORT 1, press

{PORT_1}

b.

If the switch you want to close is connected to PORT 2, press

{PORT_2}

4. Enter the switch address using the numeric keypad. In a standard

system, simply enter the channel number (1, 2, 3, or 4), and press

[Return].

More about Switch
Addresses

The “switch address” is a concatenation of the Switch Control Unit (SCU)
address (set to 0 at the factory) with the channel number (in “standard”
systems this number is 1, 2, 3, or 4).

If you just enter the channel number (1, 2, 3, or 4), the multiple channel
controller will assume that the SCU address is still at the factory default (0).
Changing SCU address requires DIP switch changes inside the SCU, and is
not necessary in standard systems. To select switch 1 (channel 1), just press

[1] [Return]

.

In custom systems with many switches, a different SCU address might be
used in part of the switch tree. Here are some example switch addresses for
complex switch trees:

101 (SCU address 1, channel 01)

212 (SCU address 2, channel 12)

312 (SCU address 3, channel 12)

Notice in the first example (101) that a two digit channel number (01) was
required. When the SCU address is set to 1, 2 or 3, you must enter a
two-digit channel number – even for channels 1 through 9.