User’s Guide ______________________________________________________________________

108 __________________________________________________________________M210785EN-E

0711-066

Figure 48

Editing Cell Properties

Editing Report Properties

The Report properties tab includes two text boxes. The Cell separator
text box indicates what kind of character is used as the column
separator. Normally it is the tabulator, marked \t. The Invalid data
indicator
text box displays the character used to indicate invalid data,
for example, a slash. This character is user-definable.

The SI Conversion option button, if selected, causes no conversion to
be performed on the selected cell; this is the default. The US
Conversion
option button, if selected, causes the conversion predefined
for the measurement unit in the selected cell to be performed. Starting
from Wizard 6.01, the US Conversion option supports one conversion,
the Kelvin-to-Celsius conversion.

For information on checksums, see section

Checksum Option in

Reports on page 203

.

On the Advanced user level, the Report properties frame also includes
an extra combo box. The Report formatting combo box offers choices
for automatic report formatting, in other words, options for packaging
or compressing reports. For further information, see section

Automatic

Report Formatting on page 169

.

0511-016

Figure 49

Editing Report Properties

Advertising