Chapter 5 ________________________________________ Advanced Use of Lizard Setup Software

VAISALA______________________________________________________________________ 153

Log Sender

With the Log sender function you can poll the logged data without
opening a service connection. Add and connect the Log sender to a
serial port in the Equipment view of Lizard.

To poll the logged data, give the following command:

LOG Lx YYMMDDhhmmss n<CR><LF>

Alternatively, you can also give the following command:

LOG Lx YYMMDDhhmmss

1

YYMMDDhhmmss

2

<CR><LF>

The QML logger responds to the LOG command with a string
including the requested log data.

For example, with the following command you can poll five records
stored to the log group L0 after 20.08.2007 at 10:30:00:

LOG L0 070820103000 5<CR><LF>

The LOG command is also available in the remote command interface,
that is, log groups can be polled through the ORBCOMM, Autotrac, and
Inmarsat-C interfaces. However, the data is limited by the capabilities
of the used communication system, for example, by the limited
character set of Autotrac.

where
Lx

=

Log group, for example, L0

YYMMDDhhmmss

=

Date and time of the requested log data

n

=

Number of records to return, starting from
the given time

where
Lx

=

Log group, for example, L0

YYMMDDhhmmss

1

=

Starting date and time of the requested log
data

YYMMDDhhmmss

2

=

Ending date and time of the requested log
data