Vaisala Hydromet Data Collection Platform User Manual

Page 180

Advertising
background image

User’s Guide ______________________________________________________________________

178 __________________________________________________________________M210785EN-E

Example 1

The timed event is executed once a minute, two seconds after a full
minute:

-

Scale: 1 (absolute)

-

Type: 1 (periodic)

-

Interval: 60000

-

Synchronization time: 2000

Example 2

The timed event is executed once a day at 06:00:

-

Scale: 1 (absolute)

-

Type: 1 (periodic)

-

Interval: 86400000

-

Synchronization time: 21600000

Example 3

The timed event is executed once, one minute after system startup:

-

Scale: 0 (relative)

-

Type: 0 (single shot)

-

Interval: 60000

-

Synchronization time: 0

Example 4 (Two Timers)

Both timed events are executed once a minute, two seconds after full
minute. Timer A starts first:

-

Scale: 1 (absolute)

-

Type: 1 (periodic)

-

Interval: 60000

-

Synchronization times: Timer A 2004, Timer B 2005