Table 25

Validation Parameters

Parameter

Description

Source and variable

Data item to be checked

Low limit

Minimum value this component
accepts

High limit

Maximum value this component
accepts

Min valid value

If set, this shows the lowest value this
component accepts, and the output is
clamped to low limit.

Max valid value

If set, this shows the highest value this
component accepts, and the output is
clamped to high limit.

Max accepted increment

Shows how much the checked values
may increase between two
consecutive readings.

Max accepted decrement

Shows how much the checked values
may decrease between two
consecutive readings.

Max consecutively refused

Shows how many times consecutive
step checks can be exceeded before
setting the output as invalid.