User’s Guide ______________________________________________________________________

130 __________________________________________________________________M210785EN-E

4.

In the Options frame, the following options are available: By
selecting the Timed report enabled check box, you can set the
alarm to be sent on a timer. This means that the report is sent not
only when the alarm condition exists but also at specified intervals.
It is usually recommended that you do not select this option. By
selecting the Generate report on each test check box, you can set
the alarm to be sent the entire time the alarm condition exists,
instead of the normal situation when the alarm report is sent only
once when the alarm condition first exists. Select the Wind
direction change alarm
check box when monitoring wind
direction values. It enables the correct handling of wind direction
limits.

NOTE

Make sure that you enter the reference value in the correct text box.
Only the values corresponding to the Test options are taken into
account.

NOTE

You can choose only one limit type for each alarm. If you want to
verify the value against multiple limits, you have to create several
separate alarms.

NOTE

The information pane with general help information is available on all
the configurable items in case you need more detailed information.