Additional notices, Warn in g – Agilent Technologies 34401A User Manual

Page 5

Advertising
background image

34401A User’s Guide

v

IEC Measurement Category II includes elec-
trical devices connected to mains at an out-
let on a branch circuit. Such devices include
most small appliances, test equipment, and
other devices that plug into a branch outlet
or socket. The 34401A may be used to make
measurements with the HI and LO inputs
connected to mains in such devices, or to
the branch outlet itself (up to 300 VAC).
However, the 34401A may not be used with
its HI and LO inputs connected to mains in
permanently installed electrical devices
such as the main circuit-breaker panel,
sub-panel disconnect boxes, or permanently
wired motors. Such devices and circuits are
subject to overvoltages that may exceed the
protection limits of the 34401A.

Note: Voltages above 300 VAC may be mea-
sured only in circuits that are isolated from
mains. However, transient overvoltages are
also present on circuits that are isolated
from mains. The Agilent 34401A are
designed to safely withstand occasional
transient overvoltages up to 2500 Vpk. Do
not use this equipment to measure circuits
where transient overvoltages could exceed
this level.

Additional Notices

Waste Electrical and
Electronic Equipment (WEEE)
Directive 2002/96/EC

This product complies with the WEEE Direc-
tive (2002/96/EC) marking requirement.
The affixed product label (see below) indi-
cates that you must not discard this electri-
cal/electronic product in domestic
household waste.

Product Category: With reference to the
equipment types in the WEEE directive
Annex 1, this product is classified as a
"Monitoring and Control instrumentation"
product.

Do not dispose in domestic household
waste.

To return unwanted products, contact your
local Agilent office, or see
www.agilent.com/environment/product
for more information.

Agilent 34138A Test Lead Set

The Agilent 34401A is compatible with the
Agilent 34138A Test Lead Set described
below.

Test Lead Ratings

Test Leads - 1000V, 15A

Fine Tip Probe Attachments - 300V, 3A

Mini Grabber Attachment - 300V, 3A

SMT Grabber Attachments - 300V, 3A

Operation

The Fine Tip, Mini Grabber, and SMT Grab-
ber attachments plug onto the probe end of
the Test Leads.

Maintenance

If any portion of the Test Lead Set is worn or
damaged, do not use. Replace with a new
Agilent 34138A Test Lead Set.

WARN IN G

If the Test Lead Set is used in a
manner not specified by Agilent
Technologies, the protection pro-
vided by the Test Lead Set may be
impaired. Also, do not use a dam-
aged or worn Test Lead Set.
Instrument damage or personal
injury may result.

Advertising