Mil output, J1939 diagnostic lamp configuration -147, Diagnostic corrective actions -147 – JLG 460SJ Service Manual User Manual

Page 199

Advertising
background image

SECTION 3 - CHASSIS & TURNTABLE

3120895

– JLG Lift –

3-147

are assigned based on the configuration outlined in Table
3-14.

MIL Output

The MIL output is used to convey fault information to the
equipment operator. The MIL is always on (grounded)
when the system is in a key-on (Vsw), engine-off state.
This provides assurance that the output is functional. If a
DTC is logged as previously-active (historic), the MIL will
send a single flash for the “Blink on-time” every “Blink off-
time.”

Diagnostic Calibration Configuration and
Corrective Actions

Each fault within the DGC is capable of being uniquely
configured in the engine.s diagnostic calibration to cause
one or more corrective actions while a given fault is active.
Table 2 identifies the configuration options and corrective
actions available for configuration of each fault. The
desired action is set by the OEM calibration engineers.

Table 3-14. J1939 Diagnostic Lamp Configuration

ECI DIAGNOSTIC ACTION

J1939 LAMP

MIL

MIL

Soft Warning

Amber

Hard Warning, Low Rev Limit,
Shutdown

Red Stop

Power Derate 1 & 2

Protect

Forced Idle

None (use in combination with
other action)

Table 3-15. Diagnostic Corrective Actions

CORRECTIVE ACTION

DESCRIPTION

Enable

Enables the fault for fault detection

Shutdown

Cause an engine shutdown when fault becomes active

Never Forget

Retain fault as historic/previously active until cleared by a technician and does not allow historic fault to be “auto-cleared”

Turn on MIL

Turn on MIL output when fault becomes active

CL Disable

Disable closed-loop while the fault is active

CL Disable Key- Cyc

Disable closed-loop while the fault is active and for the remainder of the key cycle

AL Disable

Disable adaptive learn while the fault is active

AL Disable Key-Cyc

Disable adaptive learn while the fault is active and for the remainder of the key cycle

Power Derate 1

Limit TPS to the Power Derate 1 percent set in the diagnostic calibration while the fault is active. The Power Derate 1 TPS
percent should be set higher than Power Derate 2 as Power Derate 2 adds a higher level of protection.

Power Derate 2

Limit TPS to the Power Derate 2 percent set in the diagnostic calibration while the fault is active. If the calibration is set to
“Latched for Key-Cycle” Power Derate 2 remains active until engine speed and FPP conditions are satisfied. The Power
Derate 2 TPS percent should be set lower than Power Derate 1 as Power Derate 2 adds a higher level of protection.

Low Rev Limit

Limit RPM to the Low Rev Limit speed set in the diagnostic calibration while the fault is active. If the calibration is set to
“Latched for Key-Cycle” Low Rev Limit remains active until engine speed and FPP conditions are satisfied.

Forced Idle

Limit RPM to the Forced Idle speed set in the diagnostic calibration while the fault is active and for the remainder of the key
cycle

Soft Warning

Turn on the soft warning output when the fault becomes active

Hard Warning

Turn on the hard warning output when the fault becomes active

Stopped Check

Run fault detection/checking while the engine is in a key-on, engine-off condition. NOTE: It is recommended that this fea-
ture only be used for general sensor faults (high/low voltage) and some output drivers