SECTION 6 - JLG CONTROL SYSTEM (S/N 61718 TO PRESENT)

6-52

– JLG Lift –

3120895

GEN SET CUTOUT:
13*
* Only visible if Gen Set /
Welder Menu selection is
not 0.

0

1

MOTION ENABLED: Motion enabled when generator is ON.

MOTION CUTOUT: Motion cutout in platform mode only.

0

H & T LIGHTS:
14

0

1

NO: No head and tail lights installed.

YES: Head and tail lights installed.

0

CABLE SWITCH:
15*
* Only visible under certain
model selections.
* Certain market and
model selections will alter
the default setting.

0

1

NO: No broken cable switch installed.

YES: Broken cable switch installed.

0

LOAD SYSTEM:
16*
* Only visible under certain
market selections.
* Certain market selections
will limit load system
options or alter default set-
ting.

0

1

2

3

4

NO: No load sensor installed.

WARN ONLY: Functions in creep, overload lamp lit, platform alarm beeps (5 sec ON, 2
sec OFF).

CUTOUT PLATFORM: All functions cutout, overload lamp lit, platform alarm beeps (5
sec ON, 2 sec OFF).

CUTOUT ALL: All functions cutout, flash overload light (500mS on, 500mS off), platform
alarm beeps (5 sec ON, 2 sec OFF).

SPECIAL 1: Functions in creep, overload lamp lit, disables main telescope out & main lift
up, platform alarm beeps (5 sec ON, 2 sec OFF).

0

LOAD SENSOR:
17*
* Only visible if Load Sen-
sor Menu selection is not 0
and under certain market
selections.
* Certain market selections
will limit load sensor
options.

0

1

1 ON ROTATOR: Use the on-board load sensor for all models except those which use the
Leveling Platform Module.

4 UNDER PLATFORM: Use the EIM for load sensing.

1

Table 6-5. Machine Configuration Programming Information Software Version P5.3 to P6.1