JLG 460SJ Service Manual User Manual

Page 369

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM (S/N 61718 TO PRESENT)

3120895

– JLG Lift –

6-53

FUNCTION CUTOUT:
18*
* Only visible under certain
market selections.
* Certain market selections
will limit function cutout
options or alter default set-
ting.

0

1

2

3

NO: No drive cutout.

BOOM CUTOUT: Boom function cutout while driving above elevation.

DRIVE CUTOUT: Drive & steer cutout above elevation.

DRIVE CUT E&T: Drive & steer cutout above elevation and tilted.

0

GROUND ALARM:
19*
* Certain market selections
will alter default setting.

0

1

2

3

NO: No ground alarm installed.

DRIVE: Travel alarm sounds when the drive function is active (Option).

DESCENT: Descent alarm sounds when lift down is active (Option).

MOTION: Motion alarm sounds when any function is active (Option).

3

DRIVE:
20*
* Only visible under certain
model selections.

0

1

2

4WD: Four wheel drive.

2WD: Two wheel drive.

2WD W/ 2-SPEED: Two wheel drive with 2-speed valve.

0

TEMPERATURE:
21*
* Certain market selections
will alter default setting.

0

1

CELSIUS: Celsius unit selection.

FAHRENHEIT: Fahrenheit unit selection.

1

LEVELING MODE:
22*
* Only visible on 800S
models.

0

1

ALL FUNCTIONS: Platform level with all functions.

LEVEL LIFT/TELESCOPE: Platform level on lift and telescope only.

0

4150364-18

Table 6-5. Machine Configuration Programming Information Software Version P5.3 to P6.1

Configuration Label/

Digit

Number

Description

Default

Number

Advertising
This manual is related to the following products: