Diagnostic aids – JLG 460SJ Service Manual User Manual

Page 261

Advertising
background image

SECTION 3 - CHASSIS & TURNTABLE

3120895

– JLG Lift –

3-209

DTC 9999- Throttle Actuator Failsafe Spring
Failure

• Throttle Actuator
• Check Condition- Key Off, Engine Stopped
• Fault Condition- When the key is off (or the actuator is

unpowered), the ECM is expecting the failsafe spring in
the actuator to return the throttle position to near 0%. If
the throttle does not reach this position when the actu-
ator is powered, a fault is generated.

• Corrective Action(s)- Illuminate MIL, sound audible

warning or illuminate secondary warning lamp. Govern
the engine speed to a forced idle speed.

• Non-emissions related fault

The throttle actuator has a return spring that causes the
throttle to move to a near 0% position when powered off.
This causes the engine to shutdown following a key off. If

the ECM detects the throttle position to be above x volts
when the key is off (as determined by the diagnostic cali-
bration), it will power up the actuator and attempt to drive
it to a zero position. This should ensure that the engine is
stopped.

This fault will set if the throttle does not return to a near 0%
position with the key is off.

Diagnostic Aids

• Disconnect the throttle actuator from the wire harness.

Remove the throttle actuator from the engine and man-
ually move it. Verify that the internal spring forces the
throttle back to near 0% position.

• Inspect the throttle arm or fuel rack on the fuel pump.

Verify that it is not stuck.

Electronic Throttle

Actuator w/Serial

Position Feedback

2

16

13

12

1

5V_ext

Vs=+5 VDC

5V_rtn

TPS1

TPS SER +

+

-

Motor

DBW-

DBW+

ECM

H-Bridge

19

TPS SER -

Serial

xmitter

Advertising
This manual is related to the following products: