Normally Open Switch

• Key-On, Engine On
• System Mode= “Running”

• Warm engine at idle to normal

operating temperature

• Increase RPM above limit set

in diagnostic calibration

Does DTC 524

reset ?

Intermittent Problem

No

• Key Off
• Disconnect harness from Oil Pressure switch
• Clear DTC 524
• Key On, Engine On
• System Mode= “Running”
• Operate engine et idle for at least one minute
• Increase RPM above limit set in diagnostic calibration

Yes

Does DTC 524

reset?

• Oil Pressure circuit shorted-to-ground in harness
• Faulty ECM

• Faulty Oil Pressure Switch (short circuit)
• Faulty engine oiling system (verify with

mechanical gauge)

No

Yes