LOAD SENSOR:
17*
* Only visible if Load Sen-
sor Menu selection is not 0
and under certain market
selections.
* Certain market selections
will limit load sensor
options.

0

1

1 ON ROTATOR: Use the on-board load sensor for all models except those which use the
Leveling Platform Module.

4 UNDER PLATFORM: Use the EIM for load sensing.

1

FUNCTION CUTOUT:
18*
* Only visible under certain
market selections.
* Certain market selections
will limit function cutout
options or alter default set-
ting.

0

1

2

3

NO: No drive cutout.

BOOM CUTOUT: Boom function cutout while driving above elevation.

DRIVE CUTOUT: Drive & steer cutout above elevation.

DRIVE CUT E&T: Drive & steer cutout above elevation and tilted.

0

GROUND ALARM:
19*
* Certain market selections
will alter default setting.

0

1

2

3

NO: No ground alarm installed.

DRIVE: Travel alarm sounds when the drive function is active (Option).

DESCENT: Descent alarm sounds when lift down is active (Option).

MOTION: Motion alarm sounds when any function is active (Option).

3

DRIVE:
20*
* Only visible under certain
model selections.

0

1

2

4WD: Four wheel drive.

2WD: Two wheel drive.

2WD W/ 2-SPEED: Two wheel drive with 2-speed valve.

0

TEMPERATURE:
21*
* Certain market selections
will alter default setting.

0

1

CELSIUS: Celsius unit selection.

FAHRENHEIT: Fahrenheit unit selection.

1

Table 6-6. Machine Configuration Programming Information Software Version P6.1 to Present