Table 6-2. Help Fault Codes, Displayed Faults, and Descriptions - Prior to S/N 66995

Fault Flash

Code

Communicated (Displayed on

Analyzer) Fault

Description

Priority

None

No flash code is indicated for the following help messages. They are intended to hint at a possible problem
if the vehicle is not behaving as expected.

1

EVERYTHING OK

The “normal” help message in platform mode

GROUND MODE OK

The “normal” help message in ground mode

DRIVING AT CREEP - TILTED

Drive speed is limited to creep because the vehicle is tilted.

FSW OPEN

A drive or boom function has been selected but footswitch is open.

RUNNING AT CREEP - CREEP
SWITCH OPEN

All function speeds are limited to creep because the creep switch is
open.

RUNNING AT CREEP - TILTED
AND ABOVE ELEVATION

All function speeds are limited to creep because the vehicle is tilted
and above elevation.

RUNNING AT CUTBACK - ABOVE
ELEVATION

Drive speed is limited to “ELEVATED MAX” because the vehicle is
above elevation.

TESTS ACTIVE – RECYCLE EMS
TO END

The system tests have been activated; normal vehicle operation is
not allowed.

1/1

Flash code 1/1 indicates a “sleep” mode.
NOT REQUIRED

2/1

Flash code 2/1 indicates problems with footswitch.

2

FSW FAULTY

The two foot switch signals do not agree. EMS recycle required.

KEYSWITCH FAULTY

Both platform and ground modes are selected simultaneously

2/2

Flash code 2/2 indicates problems with drive & steer selection.

3

DRIVE JOYSTICK FAULTY

The drive joystick center tap is out of valid range, or the wiper is wire-
off.

DRIVE LOCKED – JOYSTICK
MOVED BEFORE EMS/FSW

Drive was selected before and during footswitch closure.

FSW INTERLOCK TRIPPED

Footswitch was closed for seven seconds with no function selected.

STEER LOCKED – SELECTED
BEFORE EMS/FSW

Steer was selected before and during footswitch closure.

STEER SWITCHES FAULTY

Both steer switches are active together.

WAITING FOR FSW TO BE OPEN

Footswitch was closed when platform mode was selected.

JOYSTICK FAULTS – CHECK
PLATFORM BOX WIRING

More than one of the drive, lift, and swing joystick center tap or wiper
voltages is out of range. This is probably due to a short-circuit across
a joystick pot.