SECTION 3 - CHASSIS & TURNTABLE

3120895

– JLG Lift –

3-167

• Key On, Engine Running
• System Mode= “Running”

Does DTC 336 reset ?

Intermittent fault

No

Yes

Check wiring and electrical connections
between crankshaft position sensor and ECM

No

Yes

• Poor system ground
• Bad crankshaft position sensor
• Bad ECM

Operate engine at condition
that set fault based on fault
snapshot

Is crank sensor a VR/

magnetic pick-up?

Is the wiring OK?

Faulty wireharness
(twist circuit)

Is wiring between sensor

and ECM properly twisted?

No

Does fault only occur at
high operating speeds?

Yes

Increase the air gap between
sensor and trigger wheel

Yes

No

Check wiring and electrical connections
between crankshaft position sensor and ECM

No

Repair wireharness

Yes

• Poor system ground
• Bad crankshaft position sensor
• Bad ECM

Is the wiring OK?

No

Repair wireharness

Yes