SECTION 6 - JLG CONTROL SYSTEM (S/N 61718 TO PRESENT)

6-34

– JLG Lift –

3120895

4/5

Flash code 4/5 indicates problems with the S-D CAN based PVG valves
currently used on the 1250AJP only.

7

MAIN LIFT PVG COMMUNICATIONS

CAN communications lost with the Main Lift PVG valve.

tower lift pvg communications

CAN communications lost with the Tower Lift PVG valve.

tOWER TELESCOPE PVG COMUNI-
CATIONS

CAN communications lost with the Tower Telescope PVG valve.

MAIN LIFT PVG internal fault

Main boom lift pvg valve has an internal fault.

tower lift pvg internal fault

Tower boom lift pvg valve has an internal fault.

tOWER TELESCOPE PVG internal fault Tower boom telescope pvg valve has an internal fault.

MAIN LIFT PVG VALVE HIGH VOLT-
AGE

Main boom lift pvg valve has detected high excitation voltage.

TOWER LIFT PVG VALVE HIGH VOLT-
AGE

Tower boom lift pvg valve has detected high excitation voltage.

TOWER TELESCOPE PVG VALVE
HIGH VOLTAGE

Tower boom telescope pvg valve has detected high excitation voltage.

MAIN LIFT PVG VALVE LOW VOLTAGE Main boom lift pvg valve has detected low excitation voltage.

TOWER LIFT PVG VALVE LOW VOLT-
AGE

Tower boom lift pvg valve has detected low excitation voltage.

TOWER TELESCOPE PVG VALVE
LOW VOLTAGE

Tower boom telescope pvg valve has detected low excitation voltage.

MAIN LIFT PVG VALVE STUCK NEU-
TRAL

Main boom lift pvg valve detected its' spool is stuck in the neutral position.

TOWER LIFT PVG VALVE STUCK
NEUTRAL

Tower boom lift pvg valve detected its' spool is stuck in the neutral position.

TOWER TELESCOPE PVG VALVE
STUCK NEUTRAL

Tower boom telescope pvg valve detected its' spool is stuck in the neutral posi-
tion.

MAIN LIFT PVG VALVE STUCK
EXTENDED

Main boom lift pvg valve detected its' spool is stuck in the extended position.

TOWER LIFT PVG VALVE STUCK
EXTENDED

Tower boom lift pvg valve detected its' spool is stuck in the extended position.

TOWER TELESCOPE PVG VALVE
STUCK EXTENDED

Tower boom telescope pvg valve detected its' spool is stuck in the extended
position.

MAIN LIFT PVG VALVE STUCK
RETRACTED

Main boom lift pvg valve detected its' spool is stuck in the retracted position.

TOWER LIFT PVG VALVE STUCK
RETRACTED

Tower boom lift pvg valve detected its' spool is stuck in the retracted position.

TOWER TELESCOPE PVG VALVE
STUCK RETRACTED

Tower boom telescope pvg valve detected its' spool is stuck in the retracted
position.

MAIN LIFT PVG VALVE OBSTRUCTED Main boom lift pvg valve detected its' spool could not achieve command.

TOWER LIFT PVG VALVE
OBSTRUCTED

Tower boom lift pvg valve detected its' spool could not achieve command.

TOWER TELESCOPE PVG VALVE
OBSTRUCTED

Tower boom telescope pvg valve detected its' spool could not achieve com-
mand.

Table 6-3. Help Fault Codes, Displayed Faults, and Descriptions - S/N 66995 to Present