Diagnostic aids – JLG 460SJ Service Manual User Manual

Page 217

Advertising
background image

SECTION 3 - CHASSIS & TURNTABLE

3120895

– JLG Lift –

3-165

DTC 219- RPM Higher Than Max Allowed
Governed Speed

• Max Govern Speed Override- Crankshaft Position Sen-

sor

• Check Condition-Engine Running
• Fault Condition-Engine speed greater than the max

governor override speed as defined in the diagnostic
calibration

• Corrective Action(s): Sound audible warning or illumi-

nate secondary warning lamp, reduce throttle to limit
speed. Recommend closed loop and adaptive learn
fueling correction remains active during fault.

• Non-emissions related fault

This fault will set anytime the engine RPM exceeds the
limit set in the diagnostic calibration for the latch time or
more. This speed overrides any higher max governor

speeds programmed by the user. This fault is designed to
help prevent engine or equipment damage.

The throttle will be lowered in order to govern the engine
to the speed set in the diagnostic calibration.

DTC 219- RPM Higher Than Max Allowed Governed
Speed (continued)

Diagnostic Aids

NOTE: If any other DTCs are present, diagnose those first.

• Ensure that no programmed governor speeds exceed

the limit set in the diagnostic calibration for Max Gov
Override Speed

• Check mechanical operation of the throttle actuator

Electronic Throttle

Actuator w/Serial

Position Feedback

2

16

13

12

1

5V_ext

Vs=+5 VDC

5V_rtn

TPS1

TPS SER +

+

-

Motor

DBW-

DBW+

ECM

H-Bridge

19

TPS SER -

Serial

xmitter