JLG 460SJ Service Manual User Manual

Page 342

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM (S/N 61718 TO PRESENT)

6-26

– JLG Lift –

3120895

2/5

Flash code 2/5 indicates that a function is prevented due to a cutout.

4

BOOM PREVENTED — DRIVE
SELECTED

A boom function is selected while a drive function is selected and drive cutout is
configured to prevent simultaneous drive & boom operation.

DRIVE PREVENTED — ABOVE ELEVA-
TION

Drive is selected while above elevation and drive cutout is configured to pre-
vent drive.

DRIVE PREVENTED — BOOM
SELECTED

Drive is selected while a boom function is selected and drive cutout is config-
ured to prevent simultaneous drive & boom operation.

DRIVE PREVENTED — TILTED &
ABOVE ELEVATION

Drive is selected while tilted and above elevation and tilt is configured to cutout
drive.

JIB SWING PREVENTED — IN 1000#
MODE

The user is trying to jib swing in 1000# mode, which is not allowed.

CAN DONGLE ATTACHED — HYDRAU-
LICS NOT RESTRICTED

The system allows the user to operate all hydraulics with very limited restric-
tions.

MODEL CHANGED — HYDRAULICS
SUSPENDED — CYCLE EMS

User changed the model number using the analyzer. User must cycle power
before the hydraulics system will be active again.

11

BACKUP BLAM COMMUNICATIONS
ACTIVE

The serial backup communications link to the BLAM module is active

DISCONNECT ANALYZER AND
CYCLE EMS TO PERFORM BOOM
RETRIEVAL

The ground module has detected that it needs to use the RS232 backup com-
munications link to the BLAM module but an analyzer is connected. Remove
the analyzer and cycle power

FUNCTIONS LOCKED OUT - PLAT-
FORM MODULE SOFTWARE VER-
SION IMPROPER

Reported if the major version of the platform module does not match the major
version of the ground module

FUNCTIONS LOCKED OUT - CHASSIS
MODULE SOFTWARE VERSION
IMPROPER

Reported if the major version of the chassis module does not match the major
version of the ground module

FUNCTIONS LOCKED OUT - BLAM
MODULE SOFTWARE VERSION
IMPROPER

Reported if the major version of the BLAM module does not match the major
version of the ground module

2/7

Flash code 2/7 indicates that the accelerator input is faulty.
NOT REQUIRED

2/8

Flash code 2/8 indicates a problem with a hydraulic filter. Not reported
during 2 second power-up.

5

RETURN FILTER BYPASSED

Hydraulic return filter clogged

charge pump filter bypassed

Charge pump filter clogged

3/1

Flash code 3/1 indicates that a contactor did not close when energized.
NOT REQUIRED

3/2

Flash code 3/2 indicates that a contactor did not open when energized.
NOT REQUIRED

Table 6-3. Help Fault Codes, Displayed Faults, and Descriptions - S/N 66995 to Present

Fault Flash

Code

Communicated (Displayed on

Analyzer) Fault

Description

Priority