SECTION 6 - JLG CONTROL SYSTEM (S/N 61718 TO PRESENT)

6-40

– JLG Lift –

3120895

8/5

Flash code 8/5 indicates problems with the moment or load pin system.
Only occur on machines with moment or load pin control. An EMS cycle
is required.

10

MOMENT PIN HORIZONTAL FORCE
OUT OF RANGE

The horizontal force is out of the allowed range.

MOMENT PIN VERTICAL FORCE OUT
OF RANGE

The vertical force is out of the allowed range.

LOAD PIN HORIZONTAL FORCE OUT
OF RANGE

The horizontal force is out of the allowed range.

LOAD PIN VERTICAL FORCE OUT OF
RANGE

The vertical force is out of the allowed range.

MOMENT PIN SENSOR FAULT

The moment pin has reported a fault flag.

LOAD PIN SENSOR FAULT

The load pin has reported a fault flag.

NEW MOMENT PIN DETECTED
FAULT

A moment pin was detected on the system different from the one used to cali-
brate the machine.

NEW LOAD PIN DETECTED FAULT

A load pin was detected on the system different from the one used to calibrate
the machine.

Table 6-3. Help Fault Codes, Displayed Faults, and Descriptions - S/N 66995 to Present

Fault Flash

Code

Communicated (Displayed on

Analyzer) Fault

Description

Priority