SECTION 6 - JLG CONTROL SYSTEM (S/N 61718 TO PRESENT)

3120895

– JLG Lift –

6-27

3/3

Flash code 3/3 indicates a driver problem. All driver faults are detected in
a similar manner. Open circuit faults are detected when the analog feed-
back reads too high and the output is commanded off. Short to ground is
detected when the analog feedback reads low and the output is com-
manded on. Short to battery is detected when the analog feedback reads
Vbat and the output is commanded off. Not reported during 2 second
power-up. An EMS cycle is required.

6

RIGHT FORWARD DRIVE PUMP
SHORT TO GROUND

Only occurs on machines with a chassis module.

RIGHT FORWARD DRIVE PUMP
SHORT TO BATTERY

Only occurs on machines with a chassis module.

RIGHT FORWARD DRIVE PUMP
OPEN CIRCUIT

Only occurs on machines with a chassis module.

RIGHT REVERSE DRIVE PUMP
SHORT TO GROUND

Only occurs on machines with a chassis module.

RIGHT REVERSE DRIVE PUMP
SHORT TO BATTERY

Only occurs on machines with a chassis module.

RIGHT REVERSE DRIVE PUMP OPEN
CIRCUIT

Only occurs on machines with a chassis module.

LEFT FORWARD DRIVE PUMP
SHORT TO GROUND

Only occurs on machines with a chassis module.

LEFT FORWARD DRIVE PUMP
SHORT TO BATTERY

Only occurs on machines with a chassis module.

LEFT FORWARD DRIVE PUMP OPEN
CIRCUIT

Only occurs on machines with a chassis module.

LEFT REVERSE DRIVE PUMP SHORT
TO GROUND

Only occurs on machines with a chassis module.

LEFT REVERSE DRIVE PUMP SHORT
TO BATTERY

Only occurs on machines with a chassis module.

LEFT REVERSE DRIVE PUMP OPEN
CIRCUIT

Only occurs on machines with a chassis module.

ALTERNATOR/ECM POWER SHORT
TO GROUND

HOUR METER SHORT TO GROUND

HOUR METER SHORT TO BATTERY

HORN SHORT TO GROUND

HORN OPEN CIRCUIT

HORN SHORT TO BATTERY

AUX POWER SHORT TO GROUND

AUX POWER OPEN CIRCUIT

AUX POWER SHORT TO BATTERY

GLOW PLUG SHORT TO GROUND

Only occurs on machines with glow plugs configured.

GLOW PLUG OPEN CIRCUIT

Only occurs on machines with glow plugs configured.

GLOW PLUG SHORT TO BATTERY

Only occurs on machines with glow plugs configured.

LP LOCK SHORT TO GROUND

Only occurs on machines with dual-fuel engines.

LP LOCK OPEN CIRCUIT

Only occurs on machines with dual-fuel engines.

Table 6-3. Help Fault Codes, Displayed Faults, and Descriptions - S/N 66995 to Present

Fault Flash

Code

Communicated (Displayed on

Analyzer) Fault

Description

Priority