Port c feedback output – ElmoMC Gold Line Digital Servo Drives-Gold Solo Trombone User Manual
Page 100
Gold Solo Trombone Installation Guide
Technical Specifications
MAN-G-SOLTROIG (Ver. 1.3)
100
5.5.3.
Port C Feedback Output
Feature
Details
Emulated output
• A, B, Index
• Differential
Interface
RS-422
Output current capability
Maximum output current: I
OH
(max) = 2 mA
High level output voltage: V
OH
> 3.0 V
Minimum output current: I
OL
= 2 mA
Low level output voltage: V
OL
< 0.4 V
Available as options
• Emulated encoder output of any sensor on Port
A or Port B
• Daisy chain Port A or Port B
• Emulated encoder output of internal variables
• Emulated encoder outputs of the tachometer
• Emulated encoder outputs of the potentiometer
Maximum frequency
f
MAX
: 8 MHz pulses/output
Edge separation between A & B
Programmable number of clocks to allow adequate
noise filtering at remote receiver of emulated encoder
signals
Index (marker)
Length of pulse is one quadrature (one quarter of an
encoder cycle) and synchronized to A&B