Gold Solo Trombone Installation Guide

Technical Specifications

MAN-G-SOLTROIG (Ver. 1.3)

www.elmomc.com

100

5.5.3.

Port C Feedback Output

Feature

Details

Emulated output

• A, B, Index
• Differential

Interface

RS-422

Output current capability

Maximum output current: I

OH

(max) = 2 mA

High level output voltage: V

OH

> 3.0 V

Minimum output current: I

OL

= 2 mA

Low level output voltage: V

OL

< 0.4 V

Available as options

• Emulated encoder output of any sensor on Port

A or Port B

• Daisy chain Port A or Port B
• Emulated encoder output of internal variables
• Emulated encoder outputs of the tachometer
• Emulated encoder outputs of the potentiometer

Maximum frequency

f

MAX

: 8 MHz pulses/output

Edge separation between A & B

Programmable number of clocks to allow adequate
noise filtering at remote receiver of emulated encoder
signals

Index (marker)

Length of pulse is one quadrature (one quarter of an
encoder cycle) and synchronized to A&B