87

4.12. Power Up

After the Gold Solo Trombone is connected to its peripheral devices, it is ready to be powered
up.

Caution: Before applying power, ensure that
1. The DC supply is within the specified range.
2. The proper plus-minus connections are in order.
3. The VN- is not connected to the PE, when working with a non-isolated power supply.

4.12.1. Initializing the System

After the Gold Solo Trombone has been connected and mounted, the system must be set up
and initialized. This is accomplished using the Elmo Application Studio, Elmo’s Windows-based
software application. Install the application and then perform setup and initialization according
to the directions in the Elmo Application Studio User’s Manual.

4.13. Heat Dissipation

The best way to dissipate heat from the Gold Solo Trombone is to mount it so that its heatsink
faces up. For best results leave approximately 10 mm of space between the Gold Solo
Trombone‘s heatsink and any other assembly.

4.13.1. Gold Solo Trombone Thermal Data

• Heat dissipation capability (θ): Approximately 5.5 °C/W

• Thermal time constant: Approximately 600 seconds (thermal time constant means that the

Gold Solo Trombone will reach two thirds of its final temperature after 10 minutes)

• Shut-off temperature: 86 °C to 88 °C (measured on the heatsink)