Chapter 3: technical information, Technical data, Chapter 3 – ElmoMC Gold Line Digital Servo Drives-Gold Solo Trombone User Manual

Page 20: Technical information

Advertising
background image

Gold Solo Trombone Installation Guide

MAN-G-SOLTROIG (Ver. 1.3)

www.elmomc.com

20

Chapter 3:

Technical Information

3.1. Technical Data

Feature

Units 12/400 16/400 R17/400 R22/400 8/800

12/800

R11/800 R16/800

Minimum supply

voltage

VDC

S, T, or AP suffix in P/N*: 50

0 or 1 suffix in P/N: 100

S, T, or AP suffix in P/N*: 95+

Nominal supply

voltage

VDC

325

560 for 400 VAC
680 for 480 VAC

Maximum supply

voltage

VDC

400

780

Maximum continuous

power output

W

Up to 10 kW of continuous qualitative power

Efficiency at rated

power (at nominal

conditions)

%

> 98

Auxiliary supply

voltage option

VDC

18 V to 30 V

Only for Control Supply S suffix Model

Auxiliary power

supply

VA

≤5 VA without external loading

≤8 VA with full external loading

Continuous current

limit (Ic) Amplitude

sinusoidal/DC

trapezoidal

commutation

A

12

16

17

22

8

12

11

16

Sinusoidal continuous

RMS current limit (Ic)

A

8.5

11.3

12

15.5

5.7

8.5

7.8

11.3

Peak current limit

A

2 x Ic

No peak

2 x Ic

No peak

Weight

g

(oz)

362 g (12.8 oz)

Dimensions

mm

(in)

111 x 76 x 60 (4.37" x 3" x 2.36")

Digital in/Digital out/

Analog in

6/4/1

Mounting method

Panel / Wall Mounted

*See page 23 for details on the part number. The S, T, or AP suffix appears in models where
there is a 24 V control supply. If there is a 0 or 1 suffix, the control power supply operates from
the main power.