Built-in protection, Status indication, Automatic procedures – ElmoMC Gold Line Digital Servo Drives-Gold Solo Trombone User Manual

Page 93: Accessories

Advertising
background image

Gold Solo Trombone Installation Guide

Technical Specifications

MAN-G-SOLTROIG (Ver. 1.3)

www.elmomc.com

93

5.1.8.

Built-In Protection

• Software error handling

• Abort (hard stops and soft stops)

• Status reporting

• Protection against:

Shorts between motor power outputs

Shorts between motor power outputs and power input/return

Failure of internal power supplies

Over-heating

• Continuous temperature measurement. Temperature can be read on-the-fly; a warning can

be initiated x degrees before temperature disable is activated.

Over/under voltage

Loss of feedback

Following error

Current limits

5.1.9.

Status Indication

• Two outputs for bi-color LEDs

5.1.10. Automatic Procedures

• Commutation alignment

• Phase sequencing

• Current loop offset adjustment

• Current loop gain tuning

• Current gain scheduling

• Velocity loop offset adjustment

• Velocity gain tuning

• Velocity gain scheduling

• Position gain tuning

5.1.11. Accessories

Cable Kit, catalog number: CBL-GDCWHIKIT02 (can be ordered separately)

For further details, see the documentation for this cable kit (

MAN-CBLKIT-GOLD.pdf

).

Advertising