Technical Specifications

MAN-G-SOLTROIG (Ver. 1.3)

www.elmomc.com

103

5.6.3.

Digital Output Interface – PLC Mode

Feature

Details

Suffix applicable

S or 0

Type of output

Optically isolated source

Maximum supply output (VDD)

30 V

Max. output current
I

out

(max) (V

out

= Low)

I

out

(max) ≤ 500 mA for Output 1

I

out

(max) ≤ 250 mA for Outputs 2 to 4

VOL at maximum output voltage
(low level)

V

out

(on) ≤ 0.3 V

R

L

The external R

L

must be selected to limit output

current to no more than 500 mA (Output 1) or 250
mA (Outputs 2 to 4).

Executable time

0 < T < 250 µsec

Figure 43: Digital Output Schematic – for S or 0 Suffixes