Digital output interface – plc mode – ElmoMC Gold Line Digital Servo Drives-Gold Solo Trombone User Manual
Page 103
Advertising
Gold Solo Trombone Installation Guide
Technical Specifications
MAN-G-SOLTROIG (Ver. 1.3)
103
5.6.3.
Digital Output Interface – PLC Mode
Feature
Details
Suffix applicable
S or 0
Type of output
Optically isolated source
Maximum supply output (VDD)
30 V
Max. output current
I
out
(max) (V
out
= Low)
I
out
(max) ≤ 500 mA for Output 1
I
out
(max) ≤ 250 mA for Outputs 2 to 4
VOL at maximum output voltage
(low level)
V
out
(on) ≤ 0.3 V
R
L
The external R
L
must be selected to limit output
current to no more than 500 mA (Output 1) or 250
mA (Outputs 2 to 4).
Executable time
0 < T < 250 µsec
Figure 43: Digital Output Schematic – for S or 0 Suffixes
Advertising