Rockwell Automation 150 USE MN/SMC DIALOG + CONTROLLER User Manual

Page 122

Advertising
background image

Serial Communications

8-13

BT Control Buffer Layout – The following table maps integer files
starting at N10:0 with the associated M0 file location as defined in the
sample ladder logic program that follows.

BT Control Datafile

BT logical address format:

logical rack/group/slot (slot is always “0” for the 1203-GD1)

Logical address examples

Logical Rack 0, Group 0, Slot 0 = 0
Logical Rack 2, Group 4, Slot 0 = 240

This word is set by the ladder logic program. Refer to the 1747-SN scanner manual for Control Flag
Definitions.

BTW Datafile Format – A four-word data file is required to
accomplish a “Continuous Parameter Value Read.” For the example
that follows, the BTW Datafile will begin at address N10:10.

BTW Datafile

This is a fixed value, associated with the “Continuous Parameter Value Read” function.

Data Path for the BTW – Rung 2:6 of the sample ladder logic
program that follows executes a COP instruction to the M0 file to load
the necessary data for the BTW.

Address

0

1

2

3

4

5

6

7

8

9

N10:0

64

0

Address

0

1

2

3

4

5

6

7

8

9

N10:10

4

1

11

1

Address

0 1 2 3 4 5 6 7 8 9

Address

0 1 2 3 4 5 6 7 8 9

N10:0

£

M0:1.100

N10:10

£

M0:1.110

N10:20

£

M0:1.120

N10:30

£

M0:1.130

N10:40

£

M0:1.140

N10:50

£

M0:1.150

N10:60

£

M0:1.160

N10:70

£

M0:1.170

Control Flags
BT Length
BT Logical Address①

Message Length
PLC Decimal Value
Number of Parameter Values to Read
Starting Parameter Number