1-4

Product Overview

Starting Modes (cont.)

Dual Ramp Start

This starting mode is useful on applications that have varying loads
(and therefore varying starting torque requirements). Dual Ramp
Start allows the user to select between two separate Soft Start profiles
with separately adjustable ramp times and initial torque settings.

Figure 1.4 Dual Ramp Start

Full Voltage Start

This starting mode is used for applications requiring across-the-line
starting. The output voltage to the motor will reach full voltage
within 1/4 second.

Figure 1.5 Full Voltage Start

Dual Ramp Start is available only with the standard controller.

Percent

Voltage

Initial

Torque #1

100%

Start #1

Run #1

Ramp #2

Ramp #1

Start #2

Time (seconds)

Run #2

Initial

Torque #2

100%

Percent
Voltage

Time (seconds)