1-14

Product Overview

Figure 1.14 Preset Slow Speed Option

Control Options (cont.)

SMB

Smart Motor Braking Option

This option can be used in applications that require reduced stopping
times. The SMC Dialog Plus controller incorporates a
microprocessor-based system that applies braking current to a
standard squirrel cage induction motor without any additional
equipment. This option offers a user-adjustable braking current
setting from 0% to 400% of the motor’s full load current rating.
Further, it provides automatic shut-off at zero speed detection.

Figure 1.15 SMB Smart Motor Braking Option

Forward

15% – High

7% – Low

10% – Low

20% – High

Reverse

Run

Start

Time (seconds)

!

ATTENTION: Slow speed running is not intended for
continuous operation due to reduced motor cooling.

Start

Motor

Speed

100%

Run

Automatic Zero Speed

Shut-off

Brake

Smart Motor Braking

Coast-to-rest