4-44 Configuration and Programming

I:e.4 Bits 8 through 15 - Output Status

These bits reflect the current state of both the Soft and Physical
Outputs. If the Enable Output bit (M0:e.1/1) is false or if the processor
is not in run mode, the Physical Outputs are not active.

Bits 8-11 represent the Physical Outputs 0-3. Bits 12-15 represent the
Soft Outputs 4-7.

I:e.5 Next Sequencer Step, Current Sequencer Step

I:e.5 Bits 0 through 7 - Current Sequencer Step

These bits indicate the actual step position currently in effect. This
parameter is valid only when the Sequencer Mode is in effect. The
module outputs under module control will correspond to the current
step number.

For example, if the sequencer has reached step is 2, the Step 2
Outputs are active and shown in the Output Status field (I:e.4/8-15)

I:e.5 Bits 8 through 15 - Next Sequencer Step

The next valid sequencer step appears here. This parameter is only
valid when the module is in the Sequencer Mode. After the Next
Sequencer Step Preset is reached, this field is updated to the next
valid step in the sequence. If the end of the sequence was reached,
this value will be updated to the first valid step after step 0. If no valid
steps are found, a configuration error is generated.

The Next Sequencer Step corresponds to the next valid step. For
example, If step 1 has been reached and steps 2 through 4 are
disabled, 5 is the next valid step.

Next Sequencer Step and Current Sequencer Step Word 5

I:e.5

Bit Number (decimal)

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

Next Sequencer Step

Current Sequencer Step