Configuration and Programming 4-11

M0:e.3 through M0:e.8 - Range 1 through 12 Outputs (Dynamic)

Use these words to program specific on/off output patterns. The
Range 1 through Range 12 Outputs, shown below, are associated with
Ranges 1 through 12 respectively. Each output field consists of 8 bits.
The four lowest numbered bits correspond to the module’s Physical
Outputs. The four highest numbered bits correspond to the Soft
Outputs.

The Physical and Soft Output patterns are applied to the module
outputs (terminals) and Outputs Status Word (I:e.4/8-15). When a
Range Outputs bit is set to 1, the physical output will be energized if:

the Accumulated Count (I:e.1) or Rate Measurement (I:e.3) is
within the associated range

Enable Outputs (M0:e.1/1) is true (if false, but the other
conditions are true, the output bit will be set but the output will
not be energized)

the output is under module control (refer to Output Source
Select M0:e.0/1-7)

For example, while in range 2, the Range 2 Outputs (M0:e.3) bits 8-11
are applied to the module’s Physical Outputs 0-3. Bits 12-15 are
applied to the Soft Output bits 4-7. Soft Output bits (I:e.4 /12-15) may
be used in your user program as event flags.

M0:e.9 Rate Period (Dynamic)

M0:e.7

R R R

R R R R R R

Range 2 and Range 1 Outputs, Word 3

Range 4 and Range 3 Outputs Word 4

Range 6 and Range 5 Outputs, Word 5

Range 8 and Range 7 Outputs, Word 6

Range 10 and Range 9 Outputs, Word 7

M0:e.3
M0:e.4
M0:e.5
M0:e.6

Range 12 and Range 11 Outputs Word 8

M0:e.8

Physical Output Patterns

Soft Outputs Patterns

Bit Number (decimal)

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

R R R R R R R R

Rate Period, Word 9

M0:e.9

Rate Period

Bit Number (decimal)

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0