Removing the front bezel, Re-installing the front bezel, Removing the riser card assembly – Kontron CG2100 Carrier Grade Server User Manual

Page 24

Advertising
background image


23

2.

Slide the front cover toward the back cover until the tabs fit together and the

front cover is firmly in place.

3.

Install the shipping screw if tooled entry is required or if the unit will be

shipped.

4.

Reconnect all peripheral devices and the power cord(s).

CAUTION: This unit must have both covers installed when it is running to ensure proper

cooling.

Removing the Front Bezel

You need to remove the front bezel for tasks such as:

• Installing or removing hard disk drives or an SD flash card
• Observing the individual hard disk drive activity/fault indicators
• Replacing the control panel LED/switch board

The server does not have to be powered down just to remove the front bezel.

1.

Loosen the captive bezel retention screw on the right side of the bezel (“A”).

2.

Rotate the bezel to the left to free it from the pins on the front panel, as shown

in Figure 11 (“B”) and remove it.

Figure 11. Removing the Front Bezel

Re-Installing the Front Bezel

1.

Insert the tabs on the left side of the bezel into the slots on the front panel of

the chassis.

2.

Move the bezel toward the right of the front panel and align it on the front panel

pins.

3.

Snap the bezel into place and tighten the retention screw to secure it.

Removing the Riser Card Assembly

The riser card assembly cage has to be removed from the chassis to perform tasks such
as:

• Installing or replacing the riser card and any PCI add-in card(s)
• Working with any components on the server board that are near the riser card

assembly

• Removing the air duct to install or replace processors or memory DIMMs
• Removing the bridge board
• Removing the server board