5 server component replacements, 1 before you begin, Tools and supplies needed – Kontron CG2100 Carrier Grade Server User Manual

Page 60: System references, Cable routing reference, 2 replacing fans, Chapter 5, Server component replacements, 5server component replacements

Advertising
background image


59

5

Server Component Replacements

This chapter covers separately-orderable replacement spare components that you may
need to replace in your Kontron CG2100 Carrier Grade Server if they fail. For
information about what is available from Kontron, see the CG2100 Carrier Grade Server
Configuration Guide
. The latest version of the Configuration Guide is located on the
Kontron support website at

http://us.kontron.com/support/

(search for CG2100, click on

Product Downloads, then Ordering Guide).

5.1

Before You Begin

Before working with your server product, pay close attention to the safety
instructions provided in this manual. See Appendix A: Safety Information.

Warning: Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives,

boards, and other parts. We recommend that you perform all procedures in this
chapter only at an ESD workstation. If one is not available, provide some ESD
protection by wearing an antistatic wrist strap attached to chassis ground (any
unpainted metal surface) on your server when handling parts.

Tools and Supplies Needed

• #1 and #2 Phillips (cross-point) screwdrivers (or interchangeable tip screwdriver

with #1 and #2 Phillips bits)

• Personal grounding device such as an anti-static wrist strap and a grounded

conductive pad

System References

All references to left, right, front, top, and bottom assume that you are facing the
front of the server, as it would be positioned for normal operation.

Cable Routing Reference

It is important for cables to be connected correctly. See Figure 25 and Table 5 for
cable routing and for more detailed information, see the Kontron CG2100 Carrier Grade
Server Technical Product Specification
.

5.2

Replacing Fans

The fan replacement spare kit for the CG2100 server contains two 60mm fans and four
80mm fans. Each fan module is exactly like the fans in the server, i.e., the bracket
and plastic finger guard are attached. For ordering information, see the CG2100
Carrier Grade Server Configuration Guide
. The latest version of the Configuration
Guide is located on the Kontron support website at

http://us.kontron.com/support/

(search for CG2100, click on Product Downloads, then Ordering Guide).

NOTE: Before replacing any of the fans, you must remove the front chassis cover.

Because the fans are hot-swappable, you do not need to shut down the server system
and disconnect the power and external devices as is customary when removing the
top cover(s). Kontron specifies that a skilled technician can service the fans in
approximately 5 minutes.

Advertising