Re-Installing the Processor Air Duct

The air duct is required to ensure proper air flow within the chassis, so be sure that
it is in place again before re-installing the back cover.

1.

Place the processor air duct over the processor sockets and DIMMs, being careful not

to pinch any cables beneath the edges of the air duct.

2.

Slide the air duct flush with the chassis wall and the fan bracket.

3.

Re-install the riser card assembly. For instructions, see “Re-Installing the Riser

Card Assembly”.

4.

Replace the chassis back cover. For instructions, see “Re-Installing the Back

Cover”.

3.3

Internal System Components Configuration and

Installation Procedures

This section covers separately-orderable components that must be installed for your
server to operate. It also covers replacing these components and where relevant, such
as with memory DIMMs, how to configure them.

You install your separately-orderable DIMMs and processors on the Intel® Server Board
T5520UR, which is the baseboard for this server.

NOTE: Be sure to read the following detailed information about the configuration rules

and memory feature options before you begin.

Configuring Memory DIMMs

The memory DIMM slots are located in two separate banks on the T5520UR server board.
Detailed information about the memory subsystem in the CG2100 server can be found in
the Intel® Server Board S5520UR Technical Product Specification located on the Kontron
support website

http://us.kontron.com/support

(search for CG2100, click on Product

Downloads, then Technical Info). The following sections give an overview of the memory
system.

Advertising