10 installing a remote management module, Figure 44, “a”) – Kontron CG2100 Carrier Grade Server User Manual

Page 52

Advertising
background image


51

Figure 44. Installing the Personality Module

4.10

Installing a Remote Management Module

The Remote Management Module (RMM) solution for the CG2100 server has RMM3 in the iBMC
on the T5520UR server board. To use the RMM3 functionality a separately orderable GCM4
NIC must be installed at the rear of the chassis. The GCM NIC package includes a
bracket with four screws to fasten the module to the rear panel of the chassis and a
ribbon cable to connect the module to the server board.

To install the GCM NIC module you must first remove the back chassis cover, the riser
card assembly, and the processor air duct.

1.

Remove the back chassis cover. For instructions see “Removing the Back Cover” in

Section 3.2.

2.

Remove the riser card assembly (so the processor air duct can be removed). For

instructions see “Removing the Riser Card Assembly” in Section 3.2.

3.

Remove the processor air duct. For instructions, see “Removing the Processor Air

Duct” in Section 3.2.

4.

Remove the filler panel from the rear panel of the chassis by squeezing the side

edges and pulling it out. (Figure 45, “A”)