Selecting Communication Type for Port 1
When changing communication protocols on Port 1, follow the below procedure.

1. Remove power from the iQUBE

2

.

2. Place the

S2

switches in the proper position for the communication type to be used (

Off, Off

for 485/422 Half-

Duplex mode).

3. Place SW1 in the

CFG

position.

4. Apply power to the iQUBE

2

.

5. Place SW1 in the

OFF

position.

Communications Option Cards

Table 2-6 shows communications option cards available for the iQUBE

2

. Communications option cards are

installed in the J9 connector of the primary CPU board for the iQUBE

2

system. All option cards use Port 3 except

for wireless Ethernet, which uses Port 2.

Communications Cable Distance Limitations
The maximum cable lengths that can be used for various communications types depend on a number of factors.
These include output impedance of the transmitter; electrical noise in the environment; cable capacitance, wire
gauge, termination, shielding, and baud rates.

Given that these and other factors will affect the maximum usable cable length, the following distances can be used
as a general guide for iQUBE

2

communications cabling:

Data rate decreases with distance. See Table 2-8.

Ethernet port is not suitable for connection to circuits used outside the building and is subject to lightning or
power faults.

920i

Serial Option Board

J2 Connector

iQUBE

2

J7 Connector

RS-485 Signal

Pin

Pin

RS-485 Signal

RET

6

1

GND1

AR+

1

4

Tx+

AR-

2

5

Tx-

AT-

3

3

Rx-

AT+

4

2

Rx+

Table 2-5. 4-wire RS-485 connections for

920i

host

Option

PN

Fiber-optic interface card

77143

Ethernet interface card IEEE 802.3

77142

Wireless Ethernet card IEEE 802.11g

108671

USB interface card

93245

Serial interface card

108579

Table 2-6. Communications Option Cards

Cable Type

Distance

RS-232

50 ft (15 m) @ 19,200 Baud (10 ft @ 115,200 Baud)

RS-485

1000 ft (300 m) twisted pair cable @ 115,200 Baud

Fiber-optic

375 ft (114 m)

Ethernet Cat5

330 ft (100 m)

USB

16.5 ft (5 m)

802.11g

330 ft (100 m) under optimal conditions

Table 2-7. Communication Cable Limitations

Note