3 920i–iqube2 menu configuration, 920i–iqube, 3 920i–iqube – Rice Lake iQUBE2 Digital Diagnostic Junction Box User Manual

Page 26: Menu configuration, Use the, Key to specify a parameter selection, Menu as shown in figure 3-5 to select the iqube

Advertising
background image

22

iQUBE

2

Installation Manual

3.1.3 920i–iQUBE

2

Menu Configuration

Use the

LEFT

( ) and

RIGHT

( ) navigation keys to move between menu selections. Use the

DOWN

( ) and

UP

( )

navigation keys to enter and exit menu selections. Use the

ENTER

key to specify a parameter selection.

Figure 3-5. 920i Serial Menu

1. If you have multiple boards, they need to be assigned. See Section 2.7.1 on page 12.
2. Navigate through the

Serial

menu as shown in Figure 3-5 to select the iQUBE

2

to begin setup.

SCALES

SERIAL

FEATURE

PFORMT

SETPTS

DIG I/O

VERS

PORT 4

CONFIG

IQ COM1

PROGIN

CMD

SCALE

IQUBE2

IND SC

ADDRESS

BAUD

EOLDLY

4

3

1
2

See

SCALES

Screen

DISPLAY

COMM SEL

IQOPTCOM

Same as

IQ COM1

BIT 1 BIT 4

HOSTCTRL

CELHLTH

SETPNT

OFF

ZERO

TARE

NT/GRS

UNITS
PRINT

CLRCN

CLRTAR

IQ COM1

IQOPTCOM

5HZ

500HZ

2.5HZ

10HZ
15HZ
25HZ

100HZ

60HZ

30HZ

50HZ

A1

D4

A2

A3

A4

CAPACITY

SENSITV

ID

75000.00

3.000000

CELL#1

Same as A1

Number of cells depends on number of boards selected

(4 cells per board, 16 cells maximum)

(Board 1 = A, Board 2 = B, Board 3 = C, Board 4 = D)

232
422
485

RSPDLY

6

0-10

PORTTYPE

UPDATE

5HZ

2.5HZ

10HZ
15HZ
25HZ

100HZ

60HZ

30HZ

50HZ

SMPRAT

DIGIO

WARMUP

COMM

BOARDS

0

number

2

number

460800

450000

115200
230400

38400

9600

19200

57600

0

number

SCALES

CELLS