Rice Lake iQUBE2 Digital Diagnostic Junction Box User Manual

Page 47

Advertising
background image

Serial Commands

43

See Section 7.0 on page 52 for more information about data formatting commands.

Command

s = scale number

Description

Values

SCs.STREAM

Enable streaming for

iQUBE

2

port

OFF, COM1, COM2, COM1&2

SCs.GFMT

Set gross format for scale s

FMT1FMT6

SCs.NFMT

Set net format for scale s

FMT1FMT6

SCs.SFMT

Set stream format for scale s

FMT1FMT6

SCs.PFMT

Set polling format for scale s

FMT1FMT6

FMTn

Set format n

specify up to 128 characters

Table 5-4.

iQUBE

2

Data Formatting Commands

Command

s = scale number

Description

Values

SCs.GRADS

Graduations

1–100 000

SCs.CAPACITY

Returns calculated scale capacity

SCs.ZTRKBND

Zero track band

SCs.ZRANGE

Zero range

SCs.MOTBAND

Motion band

SCs.OVRLOAD

Overload

FS+2%, FS+1D, FS+9D, FS

SCs.DFSENS

Digital filter cutout sensitivity

LIGHT, MEDIUM, HEAVY

SCs.DFTHRH

Digital filter threshold count

NONE, 10, 20, 30, 50, 100, 150, 200, 250,
500, 1000, 2500, 5000, 7500, 10000, 12500,
15000

SCs.UID

Set UID of primary unit

nnnnnnn

SCs.CONSNUM

Consecutive numbering

1–9999999

SCs.CONSTUP

Consecutive number start-up value

nnnnnnn

SCs.PRI.DECPNT

Primary units decimal position

8.88888, 88.8888, 888.888, 8888.88,
88888.8, 888888, 888880, 888800

SCs.PRI.DSPDIV

Primary units display divisions

1D, 2D, 5D

SCs.PRI.UNITS

Primary units

LB, KG, OZ, TN, T, G, NONE

SCs.SEC.DECPNT

Secondary units decimal position

8.88888, 88.8888, 888.888, 8888.88,
88888.8, 888888, 888880, 888800

SCs.SEC.DSPDIV

Secondary units display divisions

1D, 2D, 5D

SCs.SEC.UNITS

Secondary units

LB, KG, OZ, TN, T, G, NONE

SCs.SEC.MULT

Secondary units multiplier

0.00001–9999.99

SCs.TAREFN

Tare function

BOTH, NOTARE, PBTARE, KEYED

SCs.REGULAT

Regulatory compliance

NTEP, OIML, CANADA, NONE

SCs.NAME

Scale name

Scale1,scale_name (24 characters, maximum)

SCs.NCELLS

Assign load cells

Order entry determines cell
pairing relationships.

0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0 (specify
comma-separated list of load cell numbers
associated with this platform) or
NONE (to
clear load cell list)

SC5.SCALES

Sets up the total scale (Scale 5)

SCs.CALMULT

Calibration multiplier

1.0, number

Table 5-5.

iQUBE

2

Scale Configuration Commands

Note

Advertising
This manual is related to the following products: