23

SERIAL Menu (PORTn,

iQUBE

Submenu)

Parameter

Choices

Description

Level 3 Submenus

COMM SEL

IQ COM1
IQOPTCOM

Selects whether to use the standard communications port (IQCOM1) or an option card
(IQOPTCOM) to communicate with the

920i

.

PORTTYPE

232
422
485

Specifies whether the selected port is used for RS-232, RS-422, or RS-485
communication.

UPDATE

30HZ
50HZ
60HZ
100HZ
2.5HZ
5HZ
10HZ
15HZ
25HZ

Update rate. Selects measurement rate, in samples per second, in which the

920i

will poll.

Level 4 Submenus

SMPRAT

30HZ
50HZ
60HZ
100HZ
500HZ
2.5HZ
5HZ
10HZ
15HZ
25HZ

Sample rate. Selects measurement rate of the analog-to-digital converter, in samples per
second. Lower sample rates provide greater signal noise immunity.

WARMUP

6
1-10

This sets a delay that causes the iQube 2 to not respond during warm up for a set amount
of time (in minutes).

DIGIO

BIT 1 - BIT 4

Specifies the function of each of the digital I/O bits.
See the Level 5 Submenus for information about digital I/O functions.

COMM

IQCOM1
IQOPTCOM

Contains parameters for the communications option specified within the COMM SEL
parameter. See parameter descriptions under Level 5 Submenus.

BOARDS

1
2
3
4

Specifies how many CPU boards are connected to the

iQUBE

.

CELLS

A1-4
B1-4
C1-4
D1-4

Contains parameters for setting the capacity, sensitivity, and ID number of each cell. The
number of cells depends on the number of boards selected in the BOARDS parameter (4
cells per board, 16 cells maximum). See parameter descriptions under Level 5 Submenus.
(Board 1=A, Board 2=B, Board 3=C, Board 4=D)

SCALES

Enters the Scale Setup screen (see Figure 3-6 on page 25) where available load cells can be
associated with the scale.

Table 3-1. Serial M

enu, PORTn,

iQUBE

Submenu Parameters