Serial Commands

41

5.0 Serial Commands

The iQUBE

2

can be controlled by a personal computer using a terminal emulation program (such as HyperTermi-

nal). Control is provided by a set of serial commands that can display and change setup parameters and perform
reporting functions. The serial commands provide the capability to print configuration data or to save that data to
an attached personal computer. This section describes the serial command set and procedures for saving and trans-
ferring data using the serial ports. The following section lists the

serial commands used to configure and control the

iQUBE

2

.

Command

Description

Values

DUMPALL

List all parameter values

DUMP.COM

List communications port parameters

DUMP.FMT

List poll and stream format parameters

DUMP.LC

List load cell parameters

DUMP.SC

List scale parameters for all scales

DUMP.SCs

List scale parameters for scale s

1–5 ( 5 = total scale)

DUMP.SP

List setpoint parameters for all setpoints

DUMP.SPn

List setpoint parameters for setpoint n

1–4

Table 5-1.

iQUBE

2

Reporting Commands

Command

Description

Values

VERSION

Write

iQUBE

2

software version

SERIAL_NUMBER

Write serial number (board ID) of primary board

MS.AUTO

Places system in MS.AUTO mode to acquire
Secondary Board IDs, and automatically assign &
download Addresses.*

MSn.ID

Reads or configures the ID of Secondary Board n
(1-3)
in the Master only.

MSn.ADDR

Reads or configures the address of Secondary
Board n (1-3) in the Master only.

MSLIST

Returns all addresses registered with the master.

MS.RESCAN

Registers the configured secondary boards with
the master. This action is automatically performed
when initializing a calibration or entering weigh
mode.

MSn yyyyyyyy zz

Configures Secondary Board n (1-3) as ID
(yyyyyyyy) and address (zz), and downloads the
address to the secondary board.* (write-only)

SMPRAT

Set sample rate

2.5HZ, 5HZ, 10HZ, 15HZ, 25HZ, 30HZ, 50HZ,
60HZ, 100HZ, 500HZ

SD

Set date (not battery-backed)

Enter using specified date format (DATEFMT)

ST

Set time (not battery-backed)

Enter using specified time format (TIMEFMT)

DATEFMT

Date format

MMDDYY, DDMMYY, YYMMDD, YYDDMM

DATESEP

Date separator

SLASH, DASH, SEMI

TIMEFMT

Time format

12HOUR, 24HOUR

TIMESEP

Time separator

COLON, COMMA

RS

Reset primary board (equivalent to cycling power) —

Table 5-2.