Rice Lake iQUBE2 Digital Diagnostic Junction Box User Manual

Page 28

Advertising
background image

24

iQUBE

2

Installation Manual

Level 5 Submenus

BIT 1 - BIT 4

OFF
ZERO
TARE
NT/GRS
UNITS
PRINT
CLRCN
CLRTAR
SETPNT
CELHLTH
HOSTCTRL

Specifies the function of each digital I/O bit.

•OFF indicates that the bit is not configured.
•ZERO, TARE, NT/GRS, UNITS, and PRINT provide the same functions as the five

major front panel keys.

•CLRCN resets the consecutive number.
•CLRTAR clears the current tare for the active scale.

•SETPNT designates the bit as a free-running setpoint within the

iQUBE

2

.

•CELHLTH designates the bit to provide cell health information.
•HOSTCTRL gives the host control over the bit’s function.

Revolution III

should be used to fully configure these parameters.

IQCOM1

ADDRESS
RSPDLY
BAUD
EOLDLY

Contains parameters for standard communications options. See parameter descriptions
under Level 6 Submenus.

A1-4
B1-4
C1-4
D1-4

CAPACITY
SENSTV
ID

CAPACITY enters the load cell’s capacity.
SENSTV enters the load cell’s actual or nominal millivolt/volt sensitivity.
ID specifies the load cell ID.

Level 6 Submenus

ADDRESS

0
number

Specifies the RS-485 address

RS-485 communications can be specified for Port 4, and for odd-
numbered expansion ports 5 and higher.

RSPDLY

2
number

Response delay (in milliseconds). Used for RS-422 2-wire communication.
Minimum value = 2.

BAUD

115200
230400
450000
460800
9600
19200
38400
57600

Baud rate. Selects the transmission speed for the port.

EOLDLY

0
0-255

End-of-line delay. Sets the delay period, in 0.1-second intervals, from when a formatted line
is terminated to the beginning of the next formatted serial output. Value specified must be in
the range 0-255, in tenths of a second (10 = 1 second).

SERIAL Menu (PORTn,

iQUBE

Submenu)

Parameter

Choices

Description

Table 3-1. Serial M

enu, PORTn,

iQUBE

Submenu Parameters

Note