Configuration

29

3.2.6 Load Cell Assignment

Once the load cells have been defined (Section 3.2.5), load
cell assignment allows up to 16 load cells to be associated
with up to four scales.

1. From the left pane, click

Load Cell Assignment

.

2. From the listing of scales, select the scale being con-

figured (Scale #1 – Scale #4).

3. Use the right arrow button to move numbered load

cells from the

Available Cells

list to the

Assigned Cells

list for that scale. (Use the left arrow button to return
a selected cell to the Available Cells list.)

4. A representation of load cell locations in the scale is

shown in the

Section Layout

portion of the display.

For all scales, use the up and down arrow buttons
to arrange the cells shown in the

Section Layout

view to reflect the physical layout of the load cells.

Section Layout

provides essential information to the

system about cell relationships. Calibration and
diagnostic functions depend on an accurate
representation of the scale.

Load cells do not have to be on the same board to be paired with each other.

3.2.7 Scale Configuration

Scale configuration can be accomplished via the

System

section in the left pane. Click

System

to expand this sec-

tion.

1. From the left pane, with the

System

section

expanded, click

Scales

.

2. From the listing of scales, click on the one to be con-

figured.

3. Use the

General

,

Formatting

,

Filtering

,

Regulatory

,

Other

,

and

Calibration

tabs to set up the scale. Refer to

Virtui

2

’s

help system for detailed instructions.

3.2.8 Additional iQUBE

2

System Configuration

Additional configuration options are available under the

System

tab for setpoints, digital inputs, and diagnostics.

Refer to Virtui

2

’s

help system for detailed information on

these options.

See Section 6.0 on page 46 for more information about
iQUBE

2

diagnostic functions.

3.2.9 Print Formatting

Print formatting parameters can be edited by clicking

For-

matting

under the

Printing

section in the left pane. The

Print-

ing

tab, when expanded, shows the Formatting selection.

This allows for consecutive numbering and custom print
tickets (gross and net).

Numbering Tab
This tab allows options for specifying consecutive
numbering options (start, next, and ID). The consecutive
number value is incremented following each print
operation that includes <CN> in the ticket format.

Section Layout

Figure 3-14.

iQUBE

2

section, Load Cell Assignment

Note

Figure 3-15. System Section, Scale — General Tab

Figure 3-16. Gross Format