Configuration

25

CONFIG Menu

1. Use the

CONFIG

menu to select the iQUBE

2

board and

cell configuration.

2. Use the

CELLS

submenu to enter load cell IDs, capaci-

ties, and factory sensitivity values (optional).

3. The Scale Setup display is divided into three areas:

Potential Scales

(center section): Highlight the scale

being configured, then use the

left

arrow key to move

to the

Available Scales

section.

Available Cells

(left section): Use this section to assign

cells to the system. Use the

UP

( ) and

DOWN

( )

keys to highlight the desired cell, then press the

Add

softkey to assign the cell.

Associated Cells

(right section): Lists cells that have

been assigned to the scale. Added cells will change
the visual representation of the scale base shown at
the bottom of the screen. Make sure the location of
the cells on the screen matches that of cells on the
actual scale to ensure diagnostic and trimming func-
tions will correctly work.

Scale 5 is the total scale. When it is highlighted, defined scales are available for summing.

4. Press

Done

to accept the configuration.

5. Continue through the

CONFIG

menu to set the sample rate, digital i/o, and communications parameters.

Associating Digital I/O

1. Use the DIGIO parameter to specify the function of each digital i/o bit. By default, Bits 1-4 are set to

OFF

.

Higher number bits (secondary boards) are set to cell health by default and cannot be changed.

Revolution III

should be used to fully configure the parameters shown in Table 3-2.

Setting COMM Parameters and Downloading Configuration

1. Use the COMM parameter to set the iQUBE

2

baud rate, end-of-line delay (0-255, in 0.1-second intervals),

and RS-485 address (not recommended for the 920i).

2. Connect to the 920i (see Section 3.1.1 on page 21).
3. Once the entire iQUBE

2

configuration is complete, press the

Download

softkey under the

Configuration

menu.

Serial configuration changes require downloading; however, changes made under the Scale menu are made in
real-time at the

iQUBE

2

.

4. Use the

UP

( ) and

DOWN

( ) keys to select

Download

iQUBE

2

configuration only

, then press

ENTER

.

Parameter

Description

OFF

The bit is not configured.

ZERO

Provides the same function as the ZERO front panel key.

TARE

Provides the same function as the TARE front panel key.

NT/GRS

Toggles between net/gross mode.

UNITS

Provides the same function as the UNITS front panel key.

PRINT

Provides the same function as the PRINT front panel key.

CLRCN

Resets the consecutive number.

CLRTAR

Clears the current tare for the active scale.

SETPNT

Designates the bit as a free-running setpoint within the

iQUBE

2

.

CELHLTH

Assigns the cell health function.

HOSTCTRL

Gives control of the bit to the host.

Table 3-2. DIGIO parameter descriptions

Figure 3-6. Scale Setup Screen

Note

Note

Note