Installation Manual

3.0 Configuration

This section describes configuration for the iQUBE

2

using the Virtui

2

Configuration Utility

,

Revolution III, 920i,

and serial commands. Instructions in this section assume that the configuration application is installed on the PC,
and that load cell and communications wiring (between multiple iQUBE

2

boards, if applicable, and between the

iQUBE

2

and the PC) is complete.

Figure 3-1. SW1 Location on CPU Board

3.1

920i Configuration

Figure 3-2. Basic

iQUBE

2

920i

Configuration flow chart

To configure the 920i indicator, the indicator must be placed in setup mode. The setup switch is accessed by
removing the large fillister head screw on the desktop and universal enclosures. Switch position is activated by
inserting a non-conductive object (such as a pen cap) into the access hole to press the switch.

When the indicator is placed in setup mode, a series of menus is shown across the top of the display, with the words

Scale Configuration

at the bottom. The iQUBE

2

is configured with the 920i indicator by using the indicator front

panel keys to navigate through a series of configuration menus. See the 920i Installation Manual for complete
information.

It is not necessary to move the

iQUBE

2

SW1 switch. It should remain in the OFF position.

Some

iQUBE

2

parameters cannot be accessed through the

920i

configuration menus.

iRev 4

provides the

most complete and efficient configuration interface for the

920i

.

Revolution III

provides access to parameters

not available in

iRev 4

or the

920i

.

Serial Number
for CPU Board

CPU Board
Fuse (F2)

SW1
Set to OFF for 920i
Set to CFG for Virtui

2

or

Revolution III

Config

Serial Port

Associate

Scale

Config

Scale

Calibr

Step 1

Step 2

Step 3

Step 4

Port

Number

iQUBE

Download

to J-Box

Cells

Scale

Select iQUBE

as Scale Type

Grads

Format

Select

Calibration

Type

²

1) Select Port Type
2) Press CONNECT

Softkey under CONFIG

Perform

Calibration

Type

²