3.0 Configuration
This section describes configuration for the iQUBE
2
using the Virtui
2
Configuration Utility
,
Revolution III, 920i,
and serial commands. Instructions in this section assume that the configuration application is installed on the PC,
and that load cell and communications wiring (between multiple iQUBE
2
boards, if applicable, and between the
iQUBE
2
and the PC) is complete.
Figure 3-1. SW1 Location on CPU Board
3.1
920i Configuration
Figure 3-2. Basic
iQUBE
2
920i
Configuration flow chart
To configure the 920i indicator, the indicator must be placed in setup mode. The setup switch is accessed by
removing the large fillister head screw on the desktop and universal enclosures. Switch position is activated by
inserting a non-conductive object (such as a pen cap) into the access hole to press the switch.
When the indicator is placed in setup mode, a series of menus is shown across the top of the display, with the words
Scale Configuration
at the bottom. The iQUBE
2
is configured with the 920i indicator by using the indicator front
panel keys to navigate through a series of configuration menus. See the 920i Installation Manual for complete
information.
It is not necessary to move the
iQUBE
2
SW1 switch. It should remain in the OFF position.
Some
iQUBE
2
parameters cannot be accessed through the
920i
configuration menus.
iRev 4
provides the
most complete and efficient configuration interface for the
920i
.
Revolution III
provides access to parameters
not available in
iRev 4
or the
920i
.
Serial Number
for CPU Board
CPU Board
Fuse (F2)
SW1
Set to OFF for 920i
Set to CFG for Virtui
2
or
Revolution III
Config
Serial Port
Associate
Scale
Config
Scale
Calibr
Step 1
Step 2
Step 3
Step 4
Port
Number
iQUBE
Download
to J-Box
Cells
Scale
Select iQUBE
as Scale Type
Grads
Format
Select
Calibration
Type
²
1) Select Port Type
2) Press CONNECT
Softkey under CONFIG
Perform
Calibration
Type
²
Designing the Scale