0 data formatting, 1 weight data formats, 1 data format tokens – Rice Lake iQUBE2 Digital Diagnostic Junction Box User Manual

Page 57: Data formatting, Data format tokens

Advertising
background image

Data Formatting

53

7.0

Data Formatting

7.1

Weight Data Formats

The following data formats are available for the iQUBE

2

: Each of the listed formats can be customized to suit the

application. The length of a format string is limited by the length of a serial input value at 128 characters.

7.1.1 Data Format Tokens

Table 7-2. Data Format Tokens

Identifier

Default Format

FMT1 (default gross format)

Scale<SC>:<CR><LF>Gross<TAB><G><CR><LF>

FMT2 (default net format)

Scale<SC>:<CR><LF>Gross<TAB><G><CR><LF>Net<TAB><N><CR><LF>
Tare<TAB><T><CR><LF>

FMT3 (default polling format)

<SC><POL><W7.><T7.><UNIT><G/N><S><D>

FMT4 (default streaming format)

<STX><POL><W7.><UNIT><G/N><S><CR><LF>

FMT5

<SC><POL><W7.><UNIT><G/N><S> | <T7.> |

FMT6

<SC><POL><W7.><UNIT><G/N><S><D> DIO:<DIO><CR><LF>

Table 7-1.

iQUBE

2

Data Formats

Token

Description

<CN>

Consecutive number
DO NOT USE FOR STREAMING/POLLING

<CR>

Carriage return character

<D>

Diagnostic event flag character (see Table 7-4
on page 54)

<DA>

Date
DO NOT USE FOR STREAMING/POLLING

<ETX>

End of text character

<G>

Gross weight, primary units

<G/A>

Gross weight, secondary units
DO NOT USE FOR STREAMING/POLLING

<G/N>

Weighing mode (gross or net)

<LF>

Line feed character

<N>

Net weight, primary units

<N/A>

Net weight, secondary units
DO NOT USE FOR STREAMING/POLLING

<NL>

New line character

<NLnn>

New line characters (1–99)

<POL>

Weight polarity

<S>

Status flag (see Table 7-3 on page 54)

<SCn>

Scale number (1–5)

<SP>

Space character

<SPnn>

Space characters (1–99)

<STX>

Start of text character

<SU>

Toggle weight data format (formatted/
unformatted)

<T>

Tare weight, primary units

<T/A>

Tare weight, secondary units
DO NOT USE FOR STREAMING/POLLING

<T5.>

Tare weight, 5-digit width

<T6.>

Tare weight, 6-digit width

<T7.>

Tare weight, 7-digit width

<T8.>

Tare weight, 8-digit width

<TAB>

Tab character

<TABnn>

Tab characters (1–99)

<TD>

Time and date
DO NOT USE FOR STREAMING/POLLING

<TI>

Time
DO NOT USE FOR STREAMING/POLLING

<UNIT>

Weight unit character (see Table 7-3)

<W5.>

Weight, 5-digit width

<W6.>

Weight, 6-digit width

<W7.>

Weight, 7-digit width

<W8.>

Weight, 8-digit width

<nnn>

ASCII character code

Token

Description

Advertising