Rice Lake iQUBE2 Digital Diagnostic Junction Box User Manual

Page 48

Advertising
background image

44

iQUBE

2

Installation Manual

Command

c = load cell number

Description

Values

LCc.ID

Load cell ID

Load Cell A1, load_cell_ID (16 characters,
maximum)

LCc.SRLNUM

Load cell serial number

(16 characters, maximum)

LCc.CAPACITY

Load cell capacity

0-1,000,000

LCc.SENS

Load cell sensitivity

0.0001–9.9999 (mV/V)

LCc.TRIM

Load cell trim factor

0–5.0000

LCc.ZERO

Load cell zero counts value

0–16777215

LCc.COUNTS

Read A/D count

LCc.CDMV

Read corrected deadload mV value

LCc.RMV

Read raw mV value

LCc.CMV

Read corrected mV value

LCc.WEIGHT

Read calibrated weight value

LCx.SAMPLEn

Uploads/Downloads calibration values for the
given (n)

Cal-Match

calibration step (

-16777215–16777215

LCx.SAMPLE

Uploads/Downloads calibration values for all
calibration steps

-16777215–16777215

Table 5-6.

iQUBE

2

Load Cell Commands

Command

s = scale number

Description

Values

SCs.CALTYPE

Calibration type

SECMATCH, CORNERMATCH, 2-
POINT

Calibration commands for CALTYPE = SECMATCH, CORNERMATCH

SCs.CAL0

Zero calibration

SCs.CALn

Calibration step n

Assign calibration step number (1–
16, maximum) for each load cell in
CORNERMATCH calibration, for
each section pair (1–8, maximum) in
SECTIONMATCH calibration

SCs.NORM

Normalize platform

Final calibration step after
completing SCs.CAL0 through
SCs.CALn

Calibration commands for CALTYPE = SINGLE, MULTI

SCs.WZERO

Zero calibration

SCs.WVAL

Platform test weight value

0–9999999

SCs.WSPAN

Platform span calibration

0–16777215

Other calibration commands

SCs.LC.CD

Set deadload coefficient

0–16777215

SCs.LC.CW

Set span coefficient

0–16777215

SCs.LC.CZ

Set temporary zero

0–16777215

SCs.REZERO

Rezero

0–16777215

SCs.LASTZERO

Last zero

0–16777215

SCs.WLIN.W1–SCs.WLIN.W5

Raw count value for linearization points 1–5

0–16777215

SCs.WLIN.V1–SCs.WLIN.V5

Test weight value for linearization points 1–5

0.000001–9999999

SCs.WLIN.C1–SCs.WLIN.C5

Calibrate linearization points 1–5

SCs.CALSPAN

Platform span calibration on

Cal-Match

scale types

Table 5-7.

iQUBE

2

Calibration Commands