2.7

Primary/Secondary Wiring and Configuration

An iQUBE

2

system can consist of up to four iQUBE

2

boards, with up to four load cell channels wired to each

board. Standard enclosures can accommodate one or two iQUBE

2

boards; large enclosures allow up to three

iQUBE

2

boards. For control of a multi-board system, one iQUBE

2

board is assigned as the primary unit and the J12

connector (M/S port) is used to provide communication between the primary and up to three secondary units.

Figure 2-3 shows the primary-to-secondary wiring for multiple iQUBE

2

boards. Successive secondary units are

wired in parallel (A to A, B to B, GND to GND) to the J12 connector of each iQUBE

2

board.

The M/S port provides RS-485 communications at approximately 450 Kbps. This port is reserved for
communication between

iQUBE

2

boards. No other devices should be connected to this port.

Figure 2-3. Primary-to-Secondary Communications Wiring

J5 Pin

J5 Signal

1

+5V

2

GND

3

I/O 1

4

I/O 2

5

I/O 3

6

I/O 4

Table 2-10. J5 Pin Assignments (Digital I/O)

J12 Pin

Primary

iQUBE

2

Secondary

iQUBE

2

1

iQA

iQA

2

iQB

iQB

3

GND2

GND2

4

GND2

GND2

Table 2-1. J12 Primary/Secondary

Port

Note

GND2

GND2

iQB

iQA

J12

CELLS 1 – 4

1

2

3

4

GND2

GND2

iQB

iQA

J12

CELLS 5 – 8

5

6

7

8

GND2

GND2

iQB

iQA

J12

CELLS 9 – 12

9

10

11

12

GND2

GND2

iQB

iQA

J12

CELLS 13 – 16

13

14

15

16

Primary iQUBE²

Secondary

iQUBE² #1

Secondary

iQUBE² #2

Secondary

iQUBE² #3

GND2

GND2

iQB

iQA

J12