System and Load Cell Tests

Overview of Typical Load Cell System

The typical system consists of one or more load cells/points, a summing junction box, and an HI 6600 Weight Processor.

Load sensor - Used to measure pressure, weight, or torque, the sensor is a strain gauge- based force
transducer that generates an electrical signal proportional to the load applied. This can be done using either
tension or compression type load sensors. When the HI 6600 sends the load cell a 5-volt DC excitation
signal that powers the load cell, the force transducer generates a millivolt output proportional to the load (0-
10mv DC for 2mv/V load cells/ points or 0-15mv DC for 3mv/V load sensor).

Weight Processor - This is part of the HI 6600 that, among other functions, powers the load cell(s)/point(s),
receives the millivolt signal output from the load cell(s)/point(s), and digitizes, interprets, communicates
and displays the results.