HI 6600 Series Modular Sensor System User Guide

Page | 12

Note: Connecting 2 or more load cells requires a summing card or Junction Box.


Non-linearity

 0.0015% of full scale

Common Mode Rejection

 110 dB at or below 60 Hz

Common Mode Voltage Range

 2.5 VDC maximum (with respect to earth ground)

Load Cell Excitation

 5 VDC +/- 1.15 VDC maximum
 Isolation from digital section 1000 VDC minimum

C2 Calibration Input

 Isolation from digital section 1000 VDC minimum

Load Sensor Cable Lengths per Weight Processing Module

 250 feet maximum of C2 authorized cable (Maximum of4 load sensors) with a Summing Card or IT

Junction box

DC Input Voltage Weight Processing Module (with 4x 350ohm load cells)

 1.72 Watts, 12-27 VDC, 71-118 mA

Maximum System Span Distance

 500 feet (150 meters) span from the first Weight Processor Module to the Hardy Gateway Module

Hardy Gateway Module (HI 6600)

Network Connectivity

 Ethernet TCP/IP

 Ethernet UDP

 Modbus-RTU over RS485

 Modbus TCP

 EtherNet/IP (EIP models only)

 Profibus-DP (PB models only)


USB Port: For Parameter Saving and Backup to PC

Display Port: For optional Front Panel Display

Scoreboard: Uses RS485 port to stream weight readings to a large display or data logger

DC Input Voltage Hardy Gateway Module (HGM)
 3.90 Watts, 12-24 VDC, 162-290 mA