Hardy HI 6600 Series Modular Sensor System User Manual

Page 33

Advertising
background image

HI 6600 Series Modular Sensor System User Guide

Page | 33

Instrument ID

Use this parameter to assign a meaningful name to the system to make it easier to identify on a network. The assignment
applies to the Gateway Module only, channels connected to the Gateway may also be assigned a name by following the
Naming the Weight Processing Modules section located in the beginning of this chapter.

Motion Tolerance Parameter


The value you enter for Motion Tolerance sets the amount of deviation to allow for your process. This value must be
greater than or equal to the Graduation Sizes. We recommend 3 times the graduation size.

The base motion number can be calculated by using the following formula:

Base Motion Number = (Total Load Cell Capacity x 0.0003)

RANGE: .000001 - 999999 (default 10)

On the Web page or Using the Front Panel Display: enter the value in the text box provided or input the desired motion
tolerance value using the arrow keys.

Operator ID Parameter

The Operator ID is the ID of the user who is going to operate the Weight Processor or service the instrument. Select three
letters or numbers or any combination of letters and numbers that adequately identifies the user.

On the Web page or Using the Front Panel Display: enter the value in the text box provided or input a value using the
arrow keys, then pressing the enter button to save.

Unit (of Measure) Parameter


The Unit (of measure) parameter sets the scale to either English or Metric units. The Selections are:

 Ounces
 Pounds
 Ton
 Gram
 Kilogram
 Metric Ton

On the Web page or Using the Front Panel Display: select the desired weight units from the pull-down list then click
Change Unit to save or select from the list of values supported using the arrow keys.